Dear experts,
when i try to create warehouse tasks, the following error appears:
"No bin search possible. Storage types/sections/bin types incomplete"
I have no idea what configuration is missing..
can somebody help me ?
Best regards,
Eike
Dear experts,
when i try to create warehouse tasks, the following error appears:
"No bin search possible. Storage types/sections/bin types incomplete"
I have no idea what configuration is missing..
can somebody help me ?
Best regards,
Eike
Hi Eike,
Please do the WT creation in the foreground by using transaction.
And if it doesn't work you can find the log and fix the problem.
Best Regards
Irfan A B
Check Outbound queue SMQ1 in ECC and Inbound queue in EWM if queue got stuck.
Check if storage type control indicator, storage section indicator is maintained in product master and related configuration is done under Goods receipt -->stretegy is done properly .
Hello all,
I am trying to generate a SSCC number for an HU. I have defined the settings at warehouse level, number range object /scwm/sscc, internal and external intervals etc. Maintained the number range for the internal interval as well.
Now when i generate a new HU in /scwm/pack, i expect the HU to use the SSCC number range but its not doing it. Instead it is looking at the number range assigned to packaging material type which I am not maintaining hence it is failing.
We do have some other warehouse in system where number ranges at pack material type are maintained.
Cant figure out why system is not proposing a number from SSCC number range.
Any ideas or hints? thanks in advance.
Regards,
Amit
Thanks irfan, thanks rajesh,
the problem was that the configuration "Define Warehouse Number Parameters for Putaway" in Goods Receipt Process --> Strategies for my storage number was set on HIGH, HIGH, HIGH .... now i changed the configurations like this:
I think some configurations that has something to do with the storage section are not ok i will check them, but now i am able to create warehouse tasks
Thank you!
best regards
eike
Dear experts,
in the following situation i try to stage materials of a production material request into my PSA. (Yes i am using the advanced production integration of EWM 9.2 )
When i am executing transaction /SCWM/STAGE the following protocol is given:
Does anyone know, what kind of configuration is missing ? Or other ideas what causes this error has ?
Best regards
Eike
Hi Gurus,
I am getting the following error "No classification is possible for the object data" when i try to create batch in EWM.
I have done required configurations and CIFed product, class, characteristics and organizational area at a time.
Please help me what else i might be missing. I dont want to create batch in ECC and want in EWM only.
Thank you....
Srini
Hi Rodrigo, For WT creation error please follow below steps. Please check Storage type control indicator, storage section indicator is maintained in product master. Then check for configuration is done under goods receipt strategy is done properly. Finally check "Define warehouse number parameters for putaway" in putaway in the goods receipt process. And strategy for my storage number was set LOW.
For stock determined in sap erp.
Check if the Availability grp configuration is correct. SPRO>EWM>GR Process>Configure availability group for putaway.
Check all the applicable nodes in this configuration and since availability grp is assigned to storage type.
Hi Srini,
Please do debug "BAPI_OBJCL_GET_KEY_OF_OBJECT" and tel which line does it go and what is the parameters. then we can find what is missing.
I think it will fail due to FM CLCA_CHECK_CLASSTYPE when you debug "BAPI_OBJCL_GET_KEY_OF_OBJECT
Hi Nikita,
Create distribution from /SPE/OL19 then it should work fine.
And also check the setting in RFC.
Hi irfan,
the WT creating error just exists because of the stock determination error..
Your tip to check the availability groups, was really good. Here are my configurations:
Defined availability Groups:
The non-location-dependent stock type:
The Stock Type configuration:
And the configuration of the storage type which my bin of the PSA belongs to:
Do you have any idea what else could be the mistake ? Or is something wrong with my configurations?
Kind regards
hi irfan,
now i tried to stage materials into the PSA and it works. I just changed the bin that is related to the PSA. The bin now, has storage type T105. The first bin was storage type T100. As you may know the new storage type is Production Supply without Stock separation. Now it works.
But do you have any idea what i have to change that Production Supply with Stock separation works ?
Kind regards
Dear experts,
i use the advanced production integration of EWM 9.2 and i have staged some materials in the PSA.
Now i want to execute the "Consumption by Production" and i am looking for the Desktop UI.
The official SAP documentation just contains a path in the NWBC menu which doesn´t exists:
EXECUTE --> Consumption by Production --> Consumption by Production
Can someone tell me why this path doesn´t exists in my menu?
Primary i am interested in the tcode for the UI to post consumption by production.
Kind regards
Rodrigo
PS: i already found the RFUI transaction, but i want the desktop UI.....
Hi Rodrigo,
please check define storage type search, storage section search, and storage bin determination.
Also check if the product is blocked in /N/SCWM/LS03 and if its blocked then unblock and try again.
Thanks and Regards
Irfan A B
Hi Nikita,
Check SMq1 and SMq2 in both system. ECC and EWM.
If SMQ1 in ECC outbound queue has queue with your del then its issue of ecc and need to check log in SLG1 for same.
If SMQ2 in ECC inbound queue has queue with your del then its issue of ecc and need to check in /SPE/OL19. and check distribution model.
If SMQ1 in EWM outbound queue has queue with your del then its issue of EWM and need to check log in SLG1 for same.
If SMQ2 in EWM inbound queue has queue with your del then its issue of EWM and need to check in /SPE/OL19. and check distribution model.
Regards
Suraj
Hello!
I have the same problem. Could you tell me, please, how did you resolve it?
Regards,
Dmitrii.