Quantcast
Channel: SCN: Message List - SAP Extended Warehouse Management (SAP EWM)
Browsing all 5578 articles
Browse latest View live

Re: Could not create header data delivery xxxxxx, system ERP_xxx

Hi, 1. Maintain the correct control cycle in ECC.2. In EWM transaction /SCWM/PSASTAGE maintain the same information along with the PSA storage bin what you maintaining in Control cycle. Also if you...

View Article


Aceeptance Sampling Issue

Hi All , I am  working  on  acceptance sampling .  I have  configured  quality  management in ECC and  EWM . The  inspection  document is not created in  Inbound  delivery in EWM.  I have maintained...

View Article


In Outbound Process Pick-Hu is not Triggered for External HU number

Hi All, At Present we have a scenerio for which we have to maintain external number for Pick-HU in outbound process which is happening fine in RFUI but in desk-top its unable to capture the...

View Article

Push data ECC to ewm

Hello, I would like to push data from a z field I added to lips table from ECC TO EWM.I enhanced the badi SMOD_V50B0001 and the method "EXIT_SAPLV50K_007" as described in the note 351303There a sample...

View Article

Image may be NSFW.
Clik here to view.

Unit of measure EA is no ock-specific (/SCWM/L3870) (Deconsolidation on RF...

Hello Experts, I am doing the deconsolidation step on RF device, while scanning the HU Quantity,   it is throwing an error like.. Help me on the same . Thanks in advance Sathish

View Article


Re: Unit of measure EA is no ock-specific (/SCWM/L3870) (Deconsolidation on...

Hi Sathish, Stock-specific UoM can be defined in EWM + Master Data + Product + Define Unit of Measurement Attributes. Regards, Philippe

View Article

Re: Unit of measure EA is no ock-specific (/SCWM/L3870) (Deconsolidation on...

Hi Philippe, Thanks for the quick reply,. its working fine. RegardsSathish

View Article

Re: Core interface - status Nosend

Suraj,You are right case closed and rewarded  RegardsRaj

View Article


Re: In Outbound Process Pick-Hu is not Triggered for External HU number

Hi Rahu, To work with pick HU on desktop, you may need to create your HU at location as your GI zone (e.g) so that when WT is confirmed, it won't be diverted to Pick HU Location. BR,Vic

View Article


Re: Inbound delivery: Overdelivery / sending process code I002 by ABAP

Dear experts I got it solved. Basically it works as already suspected via sending a process code (not exception code). This can be reached by calling the service provider with the method EXECUTE to...

View Article

Image may be NSFW.
Clik here to view.

negative stock in LS24-storage type 911- No open TO,TR, Postong change

Hi Experts, We have negative stock for a material in ls24 and there are no open TR, TO and posting Change for this material.Here is the transfer order which is confirmed 

View Article

Re: negative stock in LS24-storage type 911- No open TO,TR, Postong change

Hi, Please check if negative stock is activated in your warehouse? BR,Vic

View Article

/SCWM/MON - Warehouse Management Monitor - NEW

Experts, I am trying to create a warehouse management monitor by warehouse level - new  I just copied the standard SAP monitor and assigned the warehouse  and also i changed define methods presentation...

View Article


Re: Table Name for Quant in SAP-eWM

check the below mentioned blog shared by TK Reddy on public domain. it has detail of table as well as linkage detailhttp://blog.tkreddy.com/2012/06/28/important-sap-ewm-tables/

View Article

Re: negative stock in LS24-storage type 911- No open TO,TR, Postong change

Hi,Could you check open TR in LB11? if you find any TR, convert it into TO.if not, someone might have deleted WM document. so stock posted in IM and not cleared in WM. clear Stock inconsistent between...

View Article


Re: Table Name for Quant in SAP-eWM

Hi Rahul In EWM, the stock model is very defferent, there are LIME Index Tables, Deep LIME and EWM involved. For a physical stock in the bin, you may need to use table /SCWM/QUAN, /LIME/NQUAN Deep...

View Article

Re: negative stock in LS24-storage type 911- No open TO,TR, Postong change

Dear Victoria, Thanks for your time, Negative stock is not activated neither in plant level nor in storage location.

View Article


Net weight issue while repacking with the new HU

Hello Friends, The net weight of some of the Product has been maintained in system but when we repack while generating the new HU , there will be no net wieght information and because of this reason...

View Article

RFID Tag code generation

Dear Experts, We have suggested a EWM-Auto ID based RFID solution for warehouse automation of one of our client. The client is saying that they are not registered EPC code regulatory (for RFID Tag code...

View Article

Verification Profile & Validation Profile in Mobile Data Entry

Hi Experts, Can anyone help me with difference between  Verification Profile & Validation Profile in Mobile Data Entry? I am not able to figure out how Verification Profile is connected to...

View Article
Browsing all 5578 articles
Browse latest View live