Re: Could not create header data delivery xxxxxx, system ERP_xxx
Hi, 1. Maintain the correct control cycle in ECC.2. In EWM transaction /SCWM/PSASTAGE maintain the same information along with the PSA storage bin what you maintaining in Control cycle. Also if you...
View ArticleAceeptance Sampling Issue
Hi All , I am working on acceptance sampling . I have configured quality management in ECC and EWM . The inspection document is not created in Inbound delivery in EWM. I have maintained...
View ArticleIn Outbound Process Pick-Hu is not Triggered for External HU number
Hi All, At Present we have a scenerio for which we have to maintain external number for Pick-HU in outbound process which is happening fine in RFUI but in desk-top its unable to capture the...
View ArticlePush data ECC to ewm
Hello, I would like to push data from a z field I added to lips table from ECC TO EWM.I enhanced the badi SMOD_V50B0001 and the method "EXIT_SAPLV50K_007" as described in the note 351303There a sample...
View ArticleUnit of measure EA is no ock-specific (/SCWM/L3870) (Deconsolidation on RF...
Hello Experts, I am doing the deconsolidation step on RF device, while scanning the HU Quantity, it is throwing an error like.. Help me on the same . Thanks in advance Sathish
View ArticleRe: Unit of measure EA is no ock-specific (/SCWM/L3870) (Deconsolidation on...
Hi Sathish, Stock-specific UoM can be defined in EWM + Master Data + Product + Define Unit of Measurement Attributes. Regards, Philippe
View ArticleRe: Unit of measure EA is no ock-specific (/SCWM/L3870) (Deconsolidation on...
Hi Philippe, Thanks for the quick reply,. its working fine. RegardsSathish
View ArticleRe: Core interface - status Nosend
Suraj,You are right case closed and rewarded RegardsRaj
View ArticleRe: In Outbound Process Pick-Hu is not Triggered for External HU number
Hi Rahu, To work with pick HU on desktop, you may need to create your HU at location as your GI zone (e.g) so that when WT is confirmed, it won't be diverted to Pick HU Location. BR,Vic
View ArticleRe: Inbound delivery: Overdelivery / sending process code I002 by ABAP
Dear experts I got it solved. Basically it works as already suspected via sending a process code (not exception code). This can be reached by calling the service provider with the method EXECUTE to...
View Articlenegative stock in LS24-storage type 911- No open TO,TR, Postong change
Hi Experts, We have negative stock for a material in ls24 and there are no open TR, TO and posting Change for this material.Here is the transfer order which is confirmed
View ArticleRe: negative stock in LS24-storage type 911- No open TO,TR, Postong change
Hi, Please check if negative stock is activated in your warehouse? BR,Vic
View Article/SCWM/MON - Warehouse Management Monitor - NEW
Experts, I am trying to create a warehouse management monitor by warehouse level - new I just copied the standard SAP monitor and assigned the warehouse and also i changed define methods presentation...
View ArticleRe: Table Name for Quant in SAP-eWM
check the below mentioned blog shared by TK Reddy on public domain. it has detail of table as well as linkage detailhttp://blog.tkreddy.com/2012/06/28/important-sap-ewm-tables/
View ArticleRe: negative stock in LS24-storage type 911- No open TO,TR, Postong change
Hi,Could you check open TR in LB11? if you find any TR, convert it into TO.if not, someone might have deleted WM document. so stock posted in IM and not cleared in WM. clear Stock inconsistent between...
View ArticleRe: Table Name for Quant in SAP-eWM
Hi Rahul In EWM, the stock model is very defferent, there are LIME Index Tables, Deep LIME and EWM involved. For a physical stock in the bin, you may need to use table /SCWM/QUAN, /LIME/NQUAN Deep...
View ArticleRe: negative stock in LS24-storage type 911- No open TO,TR, Postong change
Dear Victoria, Thanks for your time, Negative stock is not activated neither in plant level nor in storage location.
View ArticleNet weight issue while repacking with the new HU
Hello Friends, The net weight of some of the Product has been maintained in system but when we repack while generating the new HU , there will be no net wieght information and because of this reason...
View ArticleRFID Tag code generation
Dear Experts, We have suggested a EWM-Auto ID based RFID solution for warehouse automation of one of our client. The client is saying that they are not registered EPC code regulatory (for RFID Tag code...
View ArticleVerification Profile & Validation Profile in Mobile Data Entry
Hi Experts, Can anyone help me with difference between Verification Profile & Validation Profile in Mobile Data Entry? I am not able to figure out how Verification Profile is connected to...