Hi RajBharti ,
Now regarding the HU weight issue , kindly check the following settings in product master :
go to /n/scwm/mat1 ->
1. enter the product no
2. Warehouse no
3. party entitled to dispose
(check in display option the following things )
Properties tab :
Measurements and weights -> (make sure the gross weight value is maintained, gross weight value = weight of 1 unit /bag like 1 bag = 50 kgs or so )
Units of Measure tab :
make sure the correct weight is maintained ( gross weight and net weight ought to be same )
UoM Category : alternative unit of measure
Whse data :
Proc . type Det.Ind : POSC
Backfl Withdrawal : No backflush withdrawal
Correlation Fix : Quantity correlation is not fixed
---------------------------------------------------------------
Make sure all these settings are maintained in the product master.
If the problem still persists , check in packing specification in TCode : /n/scwm/packspec
Best Regards